Fct. Text
Description
and settings
3.5.0 USER DATA
Submenu 3.5.0 User data
3.5.1 LANGUAGE Language
for display texts, see
Sect. 5.11
• GB/USA (English)
• D (german)
• F (French)
• N (Dutch)
3.5.2 ENTRY.CODE.
1
Entry code 1 for setting level
required?
See Sect. 5.12
• NO = Entry with
key only
• YES = Entry with
key and
9-keystroke code
Setting of the code under Fct. 3.5.3
3.5.3 CODE 1
Set Code 1, see Sect. 5.12
(appears only if YES set under Fct.
3.6.2)
• Factory setting:
→, →, →, ↵, ↵. ↵, ↑, ↑, ↑
• Different code required:
Press any 9-keystroke combination
and then press the same
combination again.
Each keystroke acknowledged by
“
*
”.
WRONG CODE appears if 1
st
and
2
nd
entries are not equal.
Press
↵ + → keys
and repeat entries.
3.5.4 LOCATION
Tag name setting
(measurement point no.)
max. 10 digits. Required only
for flowmeters of “HHC” design
(operator control via Hand-Held
Communicator MIC 500, connected
to current output).
Factory setting: ALTOMETER
Characters assignable to each
place: A..Z / a..z / 0..9 / + / -./
underscore character =
blank character.
3.5.5 OUTP. HOLD
Hold values of outputs
during settings?
Setting: NO or YES
3.5.6 UNIT
TEXT
Text
for user-defined unit
Factory setting:
hLiter/hr or US.MGal/DAY
Characters assignable
to each place:
A..Z / a..z / 0..9 / + / −-./
underscore
character = blank character.
Fraction bar ”/” in 7
th
place is
unalternable.
3.5.7 FACT. QUANT Conversion factor for quantity F
M
F
M
= quantity per 1 m
3
!
Factory setting:
1.00000 E1 (for hecto Liter)
or 2.64172 E-4 (for US M.gallons)
Value setting:
0.00001*10
−
9
- 9.99999*10
+9
3.5.8 FACT. TIME
Conversion factor for time F
T
F
T
in seconds!
Factory setting:
3.60000 E3 (for hour) or
8.64000 E4 (for day)
Value setting:
0.00001*10
−
9
- 9.99999*10
+9