Performance

Measuring Accuracy:

±2% of full-scale

Repeatability:

±.5% of full-scale

Flow Measuring Range:

5-15 GPM (19-57 LPM)

Turn Down Ratio (All Ranges):

8:1

Maximum Operating Pressure:

125 PSIG (8.6 bar)

Maximum Operating Temperature:

170°F (76°C)

Pressure Differential:

See graph on page 1

1.

Filtration Requirements:

200 Micron minimum

Materials of Construction

End Ports

PVC

Wedge Element

PVC

Pressure Sensor

Polyetherimide

Electrical Enclosure

Polycarbonate

Page

2

Page

11

Electronic Specifications

Electronic Output:

0-5/0-10 Vdc (standard), 4-20 mA (optional)

Power Requirements:

12-35 Vdc

Flow Measuring Range:

5-15 GPM (19-57 LPM)

Maximum Current Consumption:

25 mAdc

Maximum Load Resistance:

1000

Maximum Transmission Distance:

200 feet

Resolution:

12-bit

Response Time:

500 mS 10% to 90% (step change

)

Protection:

Short circuit, transient & reverse polarity

DIM

3/8" Female NPTF

1/2" Female NPTF

3/4" Female NPTF

A

6-7/8" (175mm)

6-7/8" (175mm)

7-1/2" (191mm)

B

2-7/32" (57mm)

2-7/32" (57mm)

2-7/32" (57mm)

C

1-3/32" (28mm)

1-3/32" (28 mm)

1-5/16" (34 mm)

D

5-1/4" (134mm)

5-1/4" (134mm)

5-1/4" (134mm)