System setup – Revo REVDN700-2 User Manual

Page 16

Advertising
background image

live mode. So not only reducing the recording data but also not to miss object
movement.

- No Motion(s): Adjust Interval while no motion.
- Motion (0.1s): Adjust Interval while motion exists.

<System Setup>

1) General

- Cam Info

: Display camera basic information.

NOTE:
* Cam ID/Baud rate/Protocol/Lens Type/CCD Type/Video System/Firmware Version

- System Lock: System locking by 4-characters PID (Lock/Unlock)
- Change PID: Change PID used in the system lock.

NOTE:
* Enter PID: Input previous password. Default PID is “0000”.
* Enter New PID: Input new password.
* Retype New PID: Confirm of new password.

- Title

: Change camera title. Max. 8-characters.

- Display

: Configurations for display camera ID&title.

Cam ID: Select camera ID display on/off.
Title: Select title display on/off.
Display Pos: Change position the string location.
- Language

: Change menu&OSD language.

2) Setup Tools

- System Config

Multi-Camset

: Select On (User can use 4 configuration sets)/off

Video Analytics

: Select PVA mode. (Simple PVA/ PVA+)

Communication

: Configuration for RS-485.

Cam ID

: Select the camera ID (001 - 255).

Baud Rate:

Select serial communication speed (2400/4800/9600/19200).

Protocol

: RS-485 protocol. (Auto, FASTRAX/PELCO-D/PELCO-P)

Event Out

: Off, Text-Out, FxLink

Event Strings

: Select&edit sending strings for PVA/PVA+ Events.

NOTE:
* Text Out: Send event string through RS-485 line.

This function can work with IDIS DVR’s Text-in feature.

* FxLink: Send event to PC application.

- WPC (White Pixel Compensation)

: Compensation for defected pixel on CCD.

NOTE:
* While operating on WPC, Iris will be closed automatically if you using DC/IRIS Lens.

For manual lens, you have to block the lens hole.

Static/Auto: Automatic detecting for defected pixel & compensation.

Proceeding

: Doing detection for white pixel.

NOTE:
* If brightness is too high, stop the process and print message “Bright Too High”.
* This function can compensate max. 63 points.
* If detected points are more than 63 points, repeats this detection by changes conditions.
* If more than 63 point while changing conditions, stop the process, and print “Too Many WH

Pixels”