Ar ch ive d, Includes dates before 1 1/06), Em series – Seametrics EM 101 v.1 User Manual
Page 5
Advertising

EM SERIES
101 MAGNETIC FLOW METER INSTRUCTIONS
1- 800 -975 - 8153
- +
(UNUSED)
+
+
-
-
POWER
SUPPLY
ANALOG
DEVICE
(PLC,
RECORDER,
ETC.)
4-20MA OUTPUT
(CONSULT FACTORY FOR OTHER RANGES)
LO
W ALARM
HIGH ALARM
DISPLAY
CABLE
Pulse 1
Pulse 2
Relay 2
Relay 1
NC
COM
NO
NC
NO
COM
Batch Outputs
Line
Neutral
Ground
Resume
0-5 V or
0-10 V or
4-20 mA
Start/Stop
–
+
– +
s1
+
–
s2
RESUME
COM
BATCH
Remote
Controls
Pulse Outputs
(for metering pumps)
Main
power fuse
250mA
part # 26926
AC Power
A
B
An Output
A
P
Passive
Active
Jumpers
5V
10V
4-20mA
Analog Switch
Analog Header
EM101
FT520
FT520 - EM101 BATCH CONTROL
CONNECTIONS DIAGRAM
AR
CH
IVE
D
(Includes Dates Before 1
1/06)