EM101 LOW FLOW

MAGNETIC FLOW METER

INSTRUCTIONS

www.seametrics.com

1 9 0 2 6 7 2 N D AV E S O U T H , K E N T, WA 9 8 0 3 2 U S A

( P ) 2 5 3 . 8 7 2 . 0 2 8 4 ( F ) 2 5 3 . 8 7 2 . 0 2 8 5

W W W. S E A M E T R I C S . C O M 1 . 8 0 0 . 9 7 5 . 8 1 5 3

LT - 1 1 3 1 4 - A

EM101 TROUBLESHOOTING GUIDE

Problem Possible Causes Possible Solutions

No Display

Flow rate always reads “0”

Flow rate incorrect

No power
Blown Fuse
Loose ribbon cable

Reversed flow direction
Missing ground wire
Empty pipe
Flow rate below minimum
Loose wiring or incorret wiring
Fluid conductivity <20 uS/cm

Missing or incorrect ground wire
Fluid conductivity <20 uS/cm
Empty pipe

Check for 110vac
Test fuse, replace if bad
Check robbon cable commections

Reverse flow connections
Install ground wire
Install meter in vertical position
Usr next smaller flow meter
Check connections on display board
Select other flow meter

Check for proper grounding
Select other flow meter
Install meter in vertical position

5/27/03