OPERATING ChARTS

PvC/Steel

Sch. 40

PvC/Steel

Sch. 80

Stainless

Steel (10S)

Stainless

Steel (40S)

Copper Tubing

(Type L)

Copper Tubing

(Type k)

brass Pipe

Duct. Iron

(Class 52)

EX SERIES k-FACTORS FOR vARIOuS PIPE SIZES

NomiNal PiPe Size

3”

4” 6” 8” 10” 12” 14” 16” 18” 20” 24” 30” 36”

70.397 40.985 18.130 10.497 6.674 4.709 3.900 2.989 2.364 1.904 1.319

78.748 45.360 20.084 11.495 7.322 5.184 4.297 3.281 2.588 2.094 1.451

62.385 36.626 16.510 9.642 6.173 4.373 3.620 2.756 2.169 1.762 1.223 0.784 0.576

70.397 40.985 18.130 10.497 6.674 4.661 3.827 2.893 2.263 1.819 1.249 0.791 0.580

76.371 43.552 19.513 11.201 7.230 5.016

78.371 44.638 20.223 11.622 7.500 5.239

70.672 41.517 17.778 10.445 6.674 4.661

57.376 37.320 16.915 9.503 6.197 4.325 3.189 2.443 1.931 1.565 1.088 0.747 0.520

(0.2)

(20.0)

MINIMuM AND MAXIMuM FLOW RATES IN GALLONS PER MINuTE

Feet Per

Second

NOMINAL PIPE SIZE

3”

4”

6” 8” 10” 12” 14”

16” 18” 20” 24” 30” 36”

4.5

8

18

31 49 70

96

125

159

196 282

440 635

440

783

1762 3133 4895 7050

9596 12533 15863 19584 28200 44064 63452

Note: These K-Factors are calculated using actual pipe diameters and wall thicknesses for each pipe type. They
are based on the most current testing at the time of printing. Refer to the SeaMetrics K-Factor Calculator at www.
seametrics.com for the most precise and current calculations.