INSTALLATION

Depth Setting. It is important for accuracy that the sen-
sor be inserted the correct depth into the pipe.
Follow these steps:

1. In Table 1, find Dimension C for your sensor model,
material and pipe size.

2. Subtract wall thickness of your pipe to find Dimension
D. Use Table 2 if you do not know the thickness.

3. Measuring from the outside of the pipe to the joint in
the housing, as shown in the diagram, adjust the sensor
to Dimension D and hand-tighten compression nut.

4. Align the conduit housing with the centerline of the
pipe, as shown. Be sure the arrow on the housing points
in the direction of flow.

5. Check Dimension D one more time.

6. Tighten the compression nut fully.

Caution!

Never attempt to remove a

flow sensor when there is pressure in
the pipe. Loosen the compression nut
slowly to release any trapped pressure.

If fluid sprays out when removing the sensor, stop
turning and depressurize the pipe. Failure to do
so could result in the sensor being thrown from
the pipe, resulting in damage or serious injury.