Ar ch ive d – Seametrics EX100-200 Series v.2 User Manual

Page 16

Advertising
background image

19026 72nd Ave South, kent, WA 98032 uSA

(P) 253.872.0284 (F) 253.872.0285

www.seametrics.com 1.800.975.8153

LT-11756-G

3/24/06

Problem

Probable Cause

Try...

No pulse output

Output pulses incorrect

Connect to earth ground

Check the Presence of Flow LED (see pg. 12)

Note flow direction arrow,
reverse direction to meter

Change output connections

Check plumbing

Check for proper electrical wiring

Check for power across power input terminals

Reverse connections

Select another flow meter

Check for proper gound

Check depth setting from
Dimension “C” table (page 4)

Select another flow meter

Check for full pipe or install meter in the vertical
position

Check chart on page 2

Check for air pockets or turbulence. Refer to
installation, page 2

Check for proper electical wiring

Unit not grounded

Below minimum flow cutoff

Flow reversed

Output connections reversed

Pipe not full

Excessive electrical noise

No power

Power reversed

Fluid conductivity <20 microSiemens/cm

Missing or incorrect ground wire

Incorrect depth setting

Fluid conductivity <20 microSiemens/cm

Empty pipe

Not enough straight pipe

Not enough straight pipe

Excessive electrical noise

TROubLEShOOTING

AR

CH

IVE

D

(Includes Dates 5/05 to 9/06)