Communication with external devices (continued) – SHIMPO DRI-series User Manual

Page 12

Advertising
background image

12

Communication With External Devices (continued)

External Control Command Descriptions (continued)
! APF ____________________ Auto-Power-Off

APF # CR # = 0: none

3: 3 minutes

! EXS ________________________External Input Setting

EXS # CR # = Z: TARE

H: HOLD

N: NONE

! HLD _________________ HOLD Trigger Mode

HLD # CR # = E: EDGE

L: LEVEL

O: Open Contact

C: Closed Contact

! LoG __________________ Memory Mode Setting

LoG # CR # = S: Continuous

N: Standard

! PKF __________________ PEAK Fast Mode

PKF # CR # = 0: OFF

1: ON

! DAF __________________ Analog Output Setting

DAF # CR # = 0: 1 msec

1: Display update

! ADF __________________ Filter Setting

ADF # CR # = 0: None filter

1: Normal filter

2: High filter

! D, DATN, DATT, DATC, AB, BB, BC, BD _______Data

output request (8 commands)

D

CR ....Output displayed DATA

DATN

CR ....Output average mode DATA

DATT

CR ....Output tension PEAK DATA

DATC

CR ....Output compression PEAK DATA

AB

CR ....Stop continuous data output

BB

CR ....Continuous data output

BC

CR ....Model name confirmation request

BD

CR ....Unit's confirmation request

Typical

gauge

response

! LIST ____________ Gauge’s present state

LIST

CR (Command from PC)

MDL

DRI-500 lb

Units

lb

DSPM

NORMAL

DSPT

0.125

PKFST

ON

DAFST

ON

ADFIL

NONE

OFFT

NONE

232C

4800

B8

S2

232C

PN

CR LF

X OFF

CP

ON

HLMT

50.00

LLMT

- 10.00

ET

HOLD

ET

LEVEL OPEN

LOG

CONTINUE

Gauge Response

OK

....Command accepted

ERRO

....Did not recognize command*

ERR1

....Command cannot be processed*

ERR2

....Wrong nomenclature, i.e N,S,C*

ERR3

....Communications error*

ERR7

....Memory unit error**

ERR8

....Sensor error**

IN HOLD

....When in HOLD, certain commands
cannot be processed.

IN MEMORY

....When in continuous memory mode or
standard mode (active), certain
commands can be processed.

* Check command and resend

** See troubleshooting section

UNITS CHANGE DISABLE .... This output is transmitted to
PC when someone is trying to change UNITS while memory is
accepting DATA.

Advertising