Easicool™ precision air conditioning, Dimensional & installation data, Ins ta lla tio n – Airedale EasiCool 6kW 64kW User Manual

Page 29: Dimensions

Advertising
background image

EasiCool™

Precision Air Conditioning

(1)

Standard forward airflow direction.

(2)

Optional reverse airflow direction.

(3)

Optional gland plate and panel for side services access via the right side of unit. For services details contact Airedale.

(4)

Base mains cable entry.

(5)

Standard base gland plate entry for refrigeration/water services. For services details contact Airedale.

(6)

Shaded area denotes fan discharge aperture. Optional EC fan motor discharge aperture provided with protective mesh, not shown.

(7)

M6 fixing hole positions.

(8)

Figures in brackets represent position of fan discharge aperture when larger AC fan motor option is fitted.

(9)

Figures in brackets represent optional reverse air discharge configuration when fitted with standard AC fan motors.

(10)

Figures in brackets represent position of the Fan discharge aperture when larger fan motor option is fitted.

(11)

Figures in brackets represent optional reverse air discharge configuration

67

0

A

64

0

27

0

15

20

0

B

15

200

30

A

B

A

7

B

B

30

9

10

8

19

40

670

6 - 10

990

13 - 17

1310

20 - 26

1

2

3

67

0

A

64

0

27

0

15

20

0

B

15

200

D

C

F

G

A

B

D

C

A

5

B

B

D

C

D

E

4

6

7

19

40

670

6 - 10

990

13 - 17

1310

20 - 26

1

2

6

67

0

A

64

0

27

0

15

20

0

B

15

200

D

C

F

G

A

B

D

C

A

5

B

B

D

C

D

E

4

5

3

4

Dimensional & Installation Data

Dimensions

V6 - V26 - Standard Airflow Configuration (mm) with Standard EC Fan Motors

19

40

670

6 - 10

990

13 - 17

1310

20 - 26

1

2

3

67

0

A

64

0

27

0

15

20

0

B

15

200

D

C

F

G

A

B

D

C

A

7

B

B

D

C

D

E

8

8

6

7

9

10

W x D x H

A

B

C

(10)

D

(10

)

E

F

(11)

G

(10)

V6

CW

mm

670 x 670 x 1940

640

270

216 (183)

238 (304)

N/A

50 (352)

268 (268)

V8

CW

mm

670 x 670 x 1940

640

270

183 (167)

304 (337)

N/A

50 (352)

268 (295)

V10

CW

mm

670 x 670 x 1940

640

270

167 (N/A)

337 (N/A)

N/A

50 (325)

295 (N/A)

V13

CW

mm

990 x 670 x 1940

960

590

387 (N/A)

337 (N/A)

N/A

50 (325)

295 (N/A)

V15

CW

mm

990 x 670 x 1940

960

590

355 (N/A)

401 (N/A)

N/A

50 (273)

347 (N/A)

V17

CW

mm

990 x 670 x 1940

960

590

355 (N/A)

401 (N/A)

N/A

50 (273)

347 (N/A)

V20

CW

mm

1310 x 670 x 1940

1280

455

166 (N/A)

337 (N/A)

303

50 (325)

295 (N/A)

V22

CW

mm

1310 x 670 x 1940

1280

455

166 (N/A)

337 (N/A)

303

50 (325)

295 (N/A)

V26

CW

mm

1310 x 670 x 1940

1280

455

166 (N/A)

337 (N/A)

303

50 (325)

295 (N/A)

29

EasiCool Technical Manual 7535768 V1.2.0_02_2013