Flow rate study – Badger Meter ORION AMR/AMI Hardware Solutions for Gas Utilities User Manual

Page 31

Advertising
background image

Flow Rate Study

A flow rate study is a week-long study that can be performed on an ORION Migratable or Fixed Network (in mobile mode)

endpoint to report high, low and average flow rates
A flow rate study can also be requested on the Advanced Endpoint Details screen available via the Quick Read screen

Starting a Flow Rate Study

With the optical head of the IR cable aligned with the endpoint IR LED port, tap the Start button in the Flow Rate Study section

of the IR Programming screen
Result: A message window opens to confirm the successful start of the flow rate study. The study continues for one week from the

start time and date.

Figure 37: Start Flow Rate Study

Figure 38: Flow Rate Study started

Getting Flow Rate Study Results

1 At the end of a week-long flow rate study, align the optical head of the IR cable with the endpoint IR LED port and tap

the Get button in the Flow Rate Study section of the IR Programming screen
Result: The data from the study fills in the field next to the Start, Get and Save buttons as shown. The flow study data

includes the minimum, maximum and total usage for the week.

Figure 39: Flow Rate Study results

Figure 40: Flow Rate Study results saved

2 Tap the Save button to create a file of the flow rate study data

Result: A screen display showing the location of the saved file.

3 Tap OK to close the window

IR PROGRAMMING

Page 31

April 2014

ORION® Endpoint Utility

Advertising
This manual is related to the following products: