Profile extraction, Interval readings – Badger Meter ORION AMR/AMI Hardware Solutions for Gas Utilities User Manual

Page 37

Advertising
background image

PROFILE EXTRACTION

The Profile Extraction option on the main menu gives you the ability to extract historical interval profile data from ORION

water and gas endpoints for viewing in the ORION Profile Viewer software

OTEE:

N

Extracting historical interval profile data from an ORION Migratable endpoint can be performed via IR or RF

Extracting historical interval profile data from an ORION Classic endpoint can only be performed via IR

Figure 45: Profile Extraction screen

Interval Readings

An ORION Migratable water endpoint stores 90 days of hourly readings or 22 days of readings taken at 15 minute intervals

This chart shows the number of readings collected for meters set at 60 minute (hourly) intervals and at 15 minute (quarter

hourly) intervals:

Available Profile Data

Extraction Intervals

Hourly ReadsE:

1 Read per Hour

24 Reads per Day

15 Minute ReadsE:
4 Reads per Hour
96 Reads per Day

7 days

168 reads (24 x 7)

672 (96 x 7)

14 days

336 reads (24 x 14)

1344 (96 x 14)

30 days

720 reads (24 x 30)

2160 (96 x 22 5)

60 days

1440 reads (24 x 60)

2160 (96 x 22 5)

All/90 days

2160 reads (24 x 90)

2160 reads (96 x 22 5)

An ORION Classic endpoint is capable of storing more than 20,000 historical interval readings

PROFILE EXTRACTION