16" and 20" Meters

Turbo Series Model

6600

16" (400 mm)

10000

20" (500 mm)

Meter Flanges

Raised-Face Round

Raised-Face Round

Typical Operating Range (100% ± 1.5%)

150…13,200 gpm (34 1…3000 m

3

/h)

300…19,800 gpm (68 1…4500 m

3

/h)

Typical Low Flow (95% minimum)

130 gpm (29 5 m

3

/h)

200 gpm (45 4 m

3

/h)

Maximum Continuous Flow

6600 gpm (1500 m

3

/h)

10,000 gpm (2270 m

3

/h)

Maximum Intermittent Flow

13,200 gpm (3000 m

3

/h)

19,800 gpm (4500 m

3

h)

Pressure Loss at Maximum Continuous Flow

0 5 psi (0 03 bar)

0 5 psi (0 03 bar)

Maximum Operating Pressure

150 psi (10 bar)

150 psi (10 bar)

Maximum Operating Temperature

120° F (49° C)

120° F (49° C)

Materials

Meter Housing

Blue epoxy-coated cast iron

Turbo Head

Cast iron

Nose Cone & Straightening Vanes

Thermoplastic

Rotor

Thermoplastic

Rotor Radial Bearings

Lubricated thermoplastic

Rotor Thruster Bearing

Sapphire jewels

Rotor Bearing Pivots

Passivated 316 stainless steel

Calibration Mechanism

Stainless steel & thermoplastic

Magnet

Ceramic

Register Housing & Cover

Thermoplastic or bronze

Trim

Stainless steel