Calibration Check and Adjustment

The accuracy of the Recordall Turbo Series meters is tested at the factory before shipment However, after a long period of

service, it may be necessary to recalibrate a meter The meter can be tested for accuracy using appropriate connections with

either a test tank of known volume or a test meter The meter can be tested in the setting by running output flow through

the optional test port, if so equipped The Recordall Turbo Series integral calibration mechanism can be adjusted under

line pressure, simplifying and reducing calibration time The following instructions are provided to assist in performing a

calibration check and adjustment

Accuracy Test

IF THE OPTIONAL TEST PORT IS TO BE USED, UPSTREAM AND DOWNSTREAM VALVES MUST BE CLOSED PRIOR TO

REMOVING PLUG AND INSTALLING APPROPRIATE CONNECTIONS. FAILURE TO DO SO CAN LEAD TO PLUG BEING

EJECTED FROM HOUSING, CAUSING PERSONAL INJURY AND/OR PROPERTY DAMAGE. WHEREVER AN INSTALLATION

IS EQUIPPED WITH A DRAIN VALVE FOR METER FLUSHING, OPEN THE DRAIN VALVE TO RELIEVE PRESSURE WITHIN

THE METER. IF THE INSTALLATION DOES NOT HAVE A DRAIN VALVE, CAREFULLY LOOSEN TEST PLUG UNTIL IT BEGINS

LEAKING. STOP AND WAIT FOR PRESSURE TO BLEED DOWN, THEN CONTINUE TO SLOWLY LOOSEN, MAKING CERTAIN

THE PRESSURE IS COMPLETELY BLED OFF BEFORE REMOVING.

1 After installing the appropriate connections, test the meter by closing the downstream valve (if using integral test

port) and slowly opening the upstream valve Slowly open the test circuit downstream valve to throttle flow for

test purposes

2 Place a test tank of known volume at the output of the meter An alternative is to connect a calibrated test meter to the

output Accuracy testing requires test volumes at least as large as the register test circle

3 As in testing the accuracy of any meter, the Recordall Turbo Series meter must first be purged of air by running water

through the meter

NOTE:

N

Good test practices, such as those outlined in the AWWA M6 manual, are required to perform reliable field accuracy

tests Register "jump" can occur in some instances if valves are abruptly opened or closed While this jump is

not accumulative (no affects in service billing), it can affect accuracy results (1% per division on a one test circle

volumetric test)

4 Operate the meter until the test tank is filled to the calibrated level or the predetermined quantity has registered on

the calibrated test meter Because accuracy may vary slightly with flow rate, it is recommended that the meter be

tested at low, intermediate and high flows

5 Record the quantity registered on the meter during the test
6 Perform the following calculations to determine meter accuracy:

(Quantity Registered on Meter)/(Test Tank or Test Meter Quantity) x 100=Meter Accuracy