Scope of this manual, Product information, Product description – Badger Meter Water Conditioning User Manual

Page 5: Accessories, Related literature, Scope of this manual 5, Product information 5

Advertising
background image

SCOPE OF THIS MANUAL

This manual contains installation, operation and maintenance procedures for the Badger

Meter® Recordall® Turbo Series

meters with magnetic drives To ensure efficient operation of the meters, read and understand the instructions in this manual

Retain the manual in a location where it is readily available

PRODUCT INFORMATION

Product Description

The Recordall

Turbo Series meters use proven design features such as thrust-compensated rotor geometry, direct drive

magnetic coupling, and dual outboard rotor bearings to achieve high accuracy over a broad flow range Extended product

service life is achieved at higher levels of accuracy, in addition to lower meter maintenance costs The Turbo meters are

available in 1-1/2", 2", 3", 4", 6", 8", 10", 12", 16" and 20" sizes
Incorporating unitized construction with corrosion-resistant assemblies, the basic components of the Recordall Turbo Series

consist of the housing and the completely removable measuring element The meter housing and cover plate are lead-free

bronze (1-1/2" to 10" sizes) The 12" to 20" meter housings are cast iron with a heat fused epoxy coating The measuring

element is constructed of high-impact strength thermoplastics Recordall Turbo Series meters are also equipped with an

integral calibration mechanism for in-line accuracy calibration
In the operation of a turbo meter, water flows through the straightening vanes and a nose cone at the inlet side of the meter

so that the swirling effect of upstream piping is minimized The water then strikes the rotor blades, causing the rotor to turn A

downstream nose cone includes straightening vanes to limit the downstream effects of flow profile distortions Optional NPT

test ports are provided for field performance testing
Motion of the rotor is transferred by means of a worm drive to a vertical shaft driving a gear set, which transmits the rotation

to the meter's registration device The direct drive magnetic coupling provides accurate flow registration during line surges,

and allows the permanently sealed register to be easily removed to facilitate in-line service

Accessories

Meters and encoders are compatible with Badger Meter AMR/AMI meter reading systems and other approved reading

technologies AMR/AMI solutions are available for all Recordall Turbo Series meters All reading options can be removed from

the meter without disrupting water service Badger Meter encoders provide years of reliable, accurate readings for a variety of

applications and are also available pre-wired to Badger Meter approved AMR/AMI solutions See details at

www.badgermeter.com

A strainer is recommended to provide optimal flow conditioning and protection for the measuring element An integral

strainer is available as an option for 1-1/2" through 4" meter sizes The stainless steel strainer is built into the inlet end

and includes a removable cover plate to permit easy access for routine cleaning External strainers are available in sizes 2"

through 12"

Related Literature

• The Recordall Turbo Series Meters Product Data Sheet contains information on operating principle, meter construction,

materials, tolerances and specifications

• The Recordall Turbo Series Meters Parts List contains illustrations of parts, part numbers, and part descriptions

User Manual