SPECIFICATIONS

Materials of Construction
Body and Internal Wetted Parts

316 stainless steel

Rotor

CD4MCU stainless steel

Bearings

Tungsten carbide

Rotor Shaft

Tungsten carbide

Operating Limitations

Temperature

–150…350° F (–101…177° C)

The meter should not be subjected to temperatures above 350° F (177° C), or below

–150° F (–101° C) or the freezing point of the metered liquid .

Pressure

Varies based on class of ANSI flanges used for mounting . See table below:

Flange Rating (ANSI)

150#

300#

600#

900#

1200#

Working Pressure (psi)

285

740

1480

2220

3705

Working Pressure (MPa)

1 .97

5 .10

10 .2

15 .31

25 .55

*Test Pressure (psi)

427 .5

1110

2220

3330

5557 .5

*Test Pressure (MPa)

2 .95

7 .65

15 .31

22 .96

38 .32

* Test pressure based on 1 .5 safety factor .

Accuracy

± 1 .0% of reading

Repeatability

± 0 .1%

Calibration

Water (NIST Traceable Calibration)

Corrosion

All Blancett Explosion-Proof QuikSert turbine meters are constructed of stainless steel and

tungsten carbide . The operator must ensure that the operating fluid is compatible with these

materials . Incompatible fluids can cause deterioration of internal components and cause a

reduction in meter accuracy .

Pulsation and Vibration Severe pulsation and mechanical vibration will affect accuracy and shorten the life of the meter

Filtration

If small particles are present in the fluid, Blancett recommends that a strainer be installed

upstream of the meter (see

Table 1 on page 8

for filtration recommendations) .

Compliance

Class I Div . I Groups C,D

Complies to UL1203 and CSA 22 .2 No . 30

Met Labs File No . E112860

Repair Kit

The Explosion-Proof QuikSert Turbine Flow Meter Repair Kit is designed for easy field service of

a damaged flow meter, rather than replacing the entire flow meter (see

Repair Kit Information

on page 11

) . Repair parts are constructed of stainless steel alloy and tungsten carbide and are

factory calibrated to ensure accuracy throughout the entire flow range . Each kit is complete and

includes the calibrated K factor which is used to recalibrate the flow monitor or other electronics

to provide accurate output data .

Turbine Flow Meter, Explosion-Proof QuikSert

Page 6

June 2014

TUR-UM-00287-EN-02