Figure 6, Figure 7, Pins – Badger Meter 3-A Sanitary User Manual

Page 10

Advertising
background image

Pickup Option 3

A = Power

B = Common

C = Output Signal

Pins

Pickup Option 2 & 6

Standard

Mag Pickup

(Socket End)

Amplified

Mag Pickup

(Socket End)

A = Signal

B = Signal

Pins

A - Blue (+) = Signal

B - Yellow (-) = Signal

B A

B - Black = Common

A - Red = Power (5…30V DC)

C - Green

or

Clear

= Output Pulse

(0…10V DC)

C

B

A

Figure 6: Wiring for non-NEMA 6 magnetic pickups

Pickup Option 8

Pickup Option 4

2 - Black = 0...5V DC Output

1 - Red = 10...30V DC

3 - White = Ground

3

2

4

5

1

Active Sensor

0...5V DC

(Socket End)

1 = 10...30V DC

2 = 0...5V DC Output

3 = Ground

4 = N/C

5 = N/C

Pins

2 - Black = -4...20 mA

1 - Red = +4...20 mA

3 - White = Not Used

3

2

4

5

1

Active Sensor

4...20 mA

(Socket End)

1 = Loop (+)

2 = Loop (-)

3 = N/C

4 = N/C

5 = N/C

Pins

Figure 7: Wiring for active magnetic pickups