Control. manage. optimize, Top of temperature sensor top of pressure sensor, Hedland flow transmitter – Badger Meter Digital Displays User Manual

Page 4

Advertising
background image

F6301 Pressure Sensors and F6310 Temperature Sensors

The F6234 cable is a three-pin, three-wire cable used to connect either a pressure or temperature sensor to the F6700 series displays. Only
two of the three wires in the cable are used.
1. Connect the RED wire of the F6234 cable to terminal 6 (+24 V EXC) on the F6700 series display. See

Figure 5

.

20 mA

COMM.

+24 V

EX

C.

1 2 3 4 5 6

7 8 9 10 11

F6700 / F6750

Series Display

(BLACK) - Loop

(WHITE) N.C.

(RED) + Loop

CABLE ASSEMBLY

F6234-6 6 ft (1.8 m)

F6234-15 15 ft (4.8 m)

Top of

Temperature Sensor

Top of

Pressure Sensor

1 - N/C

2 - 4 - 20 mA Out

3 - +VDC

1

2

3

1 - Case Ground

2 - 4 - 20 mA Out

3 - +VDC

1

2

3

Figure 5: Flo-tech pressure and temperature sensor wiring

2. Connect the BLACK wire of the F6234 cable to terminal 4 (20 mA) on the F6700 series display.

HEDLAND Flow Transmitter

The HN100542 cable is a four-pin, four-wire cable used to connect the HEDLAND flow transmitters to the F6700 series displays. Only two of
the four wires in the cable are used.
1. Connect the RED wire of the HN100542 cable to terminal 6 (+24 V EXC) on the F6700 series display. See

Figure 6

.

20 mA

COMM.

+24 V

EX

C.

1 2 3 4 5 6

7 8 9 10 11

F6700 / F6750

Series Display

(BLACK) - Loop

(WHITE) N.C.

(Green) N.C.

(RED) + Loop

CABLE ASSEMBLY

HN100542-15

Figure 6: HEDLAND flow transmitter wiring

2. Connect the BLACK wire of the HN100542 cable to terminal 4 (20 mA) on the F6700 series display.
After the signal wiring has been completed the F6700 series display can then be mounted in the panel and power wiring applied. See the
specific F6700 series display manual for power wiring and additional setup requirements.

www.badgermeter.com

Flo-tech and Hedland are registered trademarks of Badger Meter, Inc. Other trademarks appearing in this document are the property of their respective entities. Due to continuous

research, product improvements and enhancements, Badger Meter reserves the right to change product or system specifications without notice, except to the extent an

outstanding contractual obligation exists. © 2014 Badger Meter, Inc. All rights reserved.

The Americas | Badger Meter | 4545 West Brown Deer Rd | PO Box 245036 | Milwaukee, WI 53224-9536 | 800-876-3837 | 414-355-0400

México | Badger Meter de las Americas, S.A. de C.V. | Pedro Luis Ogazón N°32 | Esq. Angelina N°24 | Colonia Guadalupe Inn | CP 01050 | México, DF | México | +52-55-5662-0882

Europe, Middle East and Africa | Badger Meter Europa GmbH | Nurtinger Str 76 | 72639 Neuffen | Germany | +49-7025-9208-0

Europe, Middle East Branch Office | Badger Meter Europe | PO Box 341442 | Dubai Silicon Oasis, Head Quarter Building, Wing C, Office #C209 | Dubai / UAE | +971-4-371 2503

Czech Republic | Badger Meter Czech Republic s.r.o. | Maříkova 2082/26 | 621 00 Brno, Czech Republic | +420-5-41420411

Slovakia | Badger Meter Slovakia s.r.o. | Racianska 109/B | 831 02 Bratislava, Slovakia | +421-2-44 63 83 01

Asia Pacific | Badger Meter | 80 Marine Parade Rd | 21-04 Parkway Parade | Singapore 449269 | +65-63464836

China | Badger Meter | 7-1202 | 99 Hangzhong Road | Minhang District | Shanghai | China 201101 | +86-21-5763 5412

Legacy Document Number: FTLIT-553-5

Control. Manage. Optimize.

Advertising