Installation – Badger Meter High Temperature Fluid Meter User Manual

Page 8

Advertising
background image

INSTALLATION

THIS PRODUCT SHOULD BE INSTALLED AND SERVICED BY TECHNICALLY QUALIFIED PERSONNEL TRAINED IN

MAINTAINING INDUSTRIAL CLASS FLOW INSTRUMENTATION AND PROCESSING EQUIPMENT.

READ INSTRUCTIONS THOROUGHLY BEFORE INSTALLING THE UNIT. IF YOU HAVE ANY QUESTIONS REGARDING

PRODUCT INSTALLATION OR MAINTENANCE, CALL YOUR LOCAL SUPPLIER FOR MORE INFORMATION.

OIL METERS ARE NOT RECOMMENDED FOR WATER MONITORING APPLICATIONS. IF METER IS TO BE SUBJECTED TO

BOTH OIL AND WATER, WATER METERS (BRASS) ARE SUGGESTED. CONSULT FACTORY FOR DETAILS.

THIS METER MAY CONTAIN RESIDUAL AMOUNTS OF TEST FLUID AT THE TIME OF SHIPMENT. THIS FLUID SHOULD BE

REMOVED PRIOR TO INSTALLATION AS THE FLUID MAY BE INCOMPATIBLE OR HAZARDOUS WITH SOME LIQUIDS OR

GASES. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN DAMAGE TO THE EQUIPMENT.

THIS STANDARD METER IS UNIDIRECTIONAL. ATTEMPTS TO FLOW FLUIDS IN THE OPPOSITE DIRECTION OF THE FLOW

ARROW WILL RESULT IN THE METER ACTING AS A CHECK VALVE, CREATING A DEADHEADING SITUATION. IF THE

DIFFERENTIAL PRESSURE MAGNITUDE IS GREAT ENOUGH, DAMAGE TO THE INTERNAL PARTS OF THE METER WILL

RESULT.
The inline flow meter is a simple device to install . However, the following measures are recommended for reliable, trouble-

free operation:
• Align pipe accurately . Piping should be accurately aligned and of correct length . The high pressure body of the flow meter

can withstand shock and flow/pressure pulsation . However, the piping should be firmly supported by external mounting

brackets, both upstream and downstream of the meter, to avoid any pipe flexing actions that could reduce meter life .

• Use rigid mounting . If the flow meter inlet or outlet are to be rigidly mounted, and the opposing port is to be connected to

flexible hose, the end connected with the flexible hose must be rigidly mounted .

• Use Teflon® tape for sealing NPT fitting .
• Install unions . Install a union near the inlet or outlet of the meter . This will facilitate quick, easy meter removal and

inspection during periodic maintenance procedures .

• Mount the meter either horizontally or vertically (flow arrow pointing to either side or straight up) . If the meter must be

mounted inverted, special inverted scales are available from the factory .

• Ensure the fluid is traveling in the direction of the flow arrow

(Figure 1)

.

• Use at least a 200 mesh (74 micron) filter . The meter will allow particulate to pass that would jam most valves and flow

controls . Systems that do not have filtration should be equipped with at least a 200 mesh (74 micron) filter . Most hydraulic

systems already have much finer filtration .

• Dirt, ferrous metal or sealing agents, such as Teflon® tape may lodge and cause malfunction . If the meter is jammed at a

fixed position, follow cleaning and maintenance instructions .

• Do not use thread locking compounds as thread sealant .

Inline Liquid Flow Meter

Page 8

November 2013