• Do not install the flow meter near turbulence producing fittings such as elbows, reducers, close coupled valves, etc . The

inline flow meter does not require flow straighteners or special lengths of straight inlet/outlet piping to stabilize turbulent

flow patterns . However, to assure maximum operational reliability, avoid installation of elbows, valves and/or reducers

immediately adjacent to the meter inlet .

• Do not install the meter near fast-acting valves . Fast-acting valves have the potential to create high magnitude hydraulic

pressure spikes . These spikes can damage the internal components of the meter, resulting in inaccuracies or malfunction .

• Do not allow unidirectional meters to be operated against the direction of the flow arrow . The standard flow meter is an

unidirectional flow meter . The piston acts as a check valve to block flow in the reverse direction . This causes an excessive

pressure differential, which can result in damage to internal meter components . The flow meter is also available in a

modified design, which offers a reverse flow bypass feature to accommodate bidirectional flow .

OTE:

N

Inline meters with a reverse flow bypass feature are available . Consult factory for details .

Installing the Flow Meter

1 . Mount the meter so fluid is traveling in the direction of the flow arrow .

G

PM

LPM

OIL

Flow Direction

Arrow

Figure 1: Flow direction arrow

2 . Select a mounting location that is suitable for viewing and product service . To connect the flow meter into the piping

system, place an open-ended wrench onto the flow meter wrench flats adjacent to the pipe connection being installed .

DO NOT wrench on the opposite end of the flow meter or leakage may result .

Place wrench on meter flats on the same side

plumbing is being tightened

Never place wrench on meter flats opposite

plumbing being tightened

Figure 2: Installing the meter

3 . After installation, rotate the meter by hand to view the flow scale .