Repeatability

± 0.3% of full scale over recommended design flow range for all except 250B

± 0.7% of full scale over recommended design flow range for 250B

Linearity

± 0.2% of full scale over recommended design flow range for all except 250BR

± 0.7% of full scale over recommended design flow range for 250BR

Transducer Excitation

Quiescent current [email protected] to 35.0VDC max.

Quiescent voltage (Vhigh) Supply Voltage -(600uA*Supply impedance)

ON state (VLow) Max. 1.2VDC@40mA current limit (15Ω+0.7VDC)

Output Frequency

3.2 Hz to 200 Hz for all except 250BR

0.8 Hz to 80 Hz for 250BR

Output Pulse Width

5 msec ±25%

Square wave between 100Hz to 200Hz limit

Electrical Cable for Standard Sensor Electronics

20 feet of 2-conductor 20 AWG shielded U.L. type PTLC wire provided for connection to display or analog transmitter
unit. Rated to 1050C. May be extended to a maximum of 2000 feet with similar cable and insulation appropriate for
application.

Electrical Cable for IR Sensor Electronics

48 inches of U.L. Style 116666 copper solid AWG 18 wire with direct burial insulation. Rated to 105oC.