Badger Meter Series 4000 Sensor - 1/2, 3/4", 1" User Manual

Page 15

Advertising
background image

O-Rings

• Viton

®

• EPDM

• Kalrez

®

Silicon - food grade

• Neoprene

®

• Chemraz

®

• Teflon

®

Encapsulated Viton

Impeller Shafts

• Zirconia

Ceramic

• Hastelloy

®

- C-276

Tungsten Carbide - GE carboloy 883 colbalt binder

Titanium - titanium alloy 86Ti-6AL-6V-25A

• Monel

®

- Grade K500

Stainless Steel - 316 stainless steel

Tantalum - commercial grade

Process Connections

PVC (virgin polyvinyl chloride, type 1, grade 1) schedule 80 tail pieces

PVDF (virgin polyvinylidene fluoride) sockets

PVDF union thread (for joining existing piping systems with GF unions)

PVDF union nuts with socket union ends

PVDF union nuts with 316 stainless steel FNPT union ends

• PVDF

flanges

PVDF union nuts with CPVC socket union ends

Impeller and Bearing

• Tefzel

®

Pressure, Temperature Ratings

Depends on hardware configurations. See diagram at end of this section.

Operating Flow Range

0 to 20 ft/sec for standard range units

0 to 10 ft/sec for enhanced flow range units

Recommended Design Flow Range

1 to 20 ft/sec for standard range units to maintain calibration accuracy

0.25 to 8 ft/sec for enhanced flow range units to maintain calibration accuracy

Accuracy

Better than +/- 1.0% of full scale over recommended design flow range with water @50-80 F and 20-40 psig

Repeatability

+/- 0.5% of full scale over recommended design flow range

Installation & Operation Manual

Page 15

April 2012

Advertising