9 . Install the instrument valves (optional) at the AF Ellipse head connections . Make sure the valves are FULLY CLOSED to

prevent them from leaking during startup .

INSTALLATION INSTRUCTIONS, DOUBLE SUPPORT

1 . Follow steps 1 through 5 in “Installation Instructions, Single Support” . At 180° from and on the same plane as the

previously drilled hole, grind the surface of the pipe to provide a clean area for welding . Drill a hole and deburr, especially

on the inside of the pipe . The hole used for the double support should be sized according to

Table 3

.

Model / Sensor

Weld Connector

Drill Bit

AF (7/8")

1/2"

1/2"

AF1 (1-1/4")

1"

7/8"

AF2 (2-1/4")

3"

2-3/4"

Table 3: Double support drill bit size

2 . Weld the double support weld-o-let or thread-o-let making sure that it is centered with the drilled hole and the low point

on the bottom of the weld-o-let or thread-o-let is in line with the pipe centerline (1/16" weld gap recommended) .

3 . Install the AF Ellipse sensor through the two holes . Make sure that the double support pin passes through the guide ring .

See

Figure 6

.

Models AF & AF1

Ellipse Sensor

Thread-o-let

Double Support

Pin

Guide

Ring

Plug

Weld-o-let

Ellipse Sensor

Double Support

Pin

Guide

Ring

Cap

Model AF2

Figure 6: Double support pin

4 . Align the arrow located on the sensor head in the direction of flow as in step 7,

“Installation Instructions, Single Support” on

page 5

.

5 . Install and tighten all nuts and bolts (provided) . Bolt torques should be in accordance with applicable standards .
6 . Install the plug into the end of the double support thread-o-let* (weld on cap for AF2) . Tighten the plug to

prevent leakage .

OTEE:

N

* Use a thread sealant suitable for the process when making this connection .

Ellipse® Pitot Tube Meter, AF Annular Flanged Meter