The Preso patented elliptical design outperforms and provides greater

accuracy than traditional differential pressure flow measurement devices .

This differential pressure flow meter is designed with a series of ports facing

the upstream velocity pressures, as well as flow sensing ports strategically

located ahead of the trailing edge flow separation .
The multi-ported, self-averaging flow element consists of an elliptical shape

with two independent flow sensing chambers . The impact velocity sensing

holes (high pressure) are located along the leading edge and the true static

sensing holes (low pressure) are on the exterior probe side . Model AS comes

with instrument shutoff valves with provisions to accept a transmitter or

direct indicating meter .

True static

sensing holes

Impact velocity

sensing holes

Figure 1: AS pressure sensing holes

SPECIFICATIONS

Applications

Steam

Pipe Sizes

2…48 inches (50…1220 mm)

Pressure

600 psi (4100 kPa) maximum

Temperature

480° F (250° C) maximum

Accuracy

±0 .75% of reading

Turndown Ratio

17:1 with no vacuum effect

Standard Components

T-type head, 316 SS 1/2" FNPT connection
CS compression fitting with SS ferrule
CS 3000 lb weld fitting, ASTM A105
316/316L SS Ellipse sensor
316 SS ID tag with wire

Reynolds Number

Greater than 75,000 maintains most accurate flow measurements
Less than 75,000 consult factory for estimated results

Resonance

If greater than 0 .8, use double support .

Table 1: Specifications