INTRODUCTION

The Preso patented elliptical design outperforms and provides greater

accuracy than traditional differential pressure flow measurement devices .

This differential pressure flow meter is designed with a series of ports

facing the upstream velocity pressures, as well as flow sensing ports

strategically located ahead of the trailing edge flow separation .
The multi-ported, self-averaging flow element consists of an elliptical

shape with two independent flow sensing chambers . The impact velocity

sensing holes (high pressure) are located along the leading edge and the

true static sensing holes (low pressure) are on the exterior probe side .

The BAR Ellipse comes with instrument shutoff valves with provisions to

accept a transmitter or direct indicating meter .

Impact velocity

sensing holes

True static

sensing holes

Figure 1: BAR Ellipse pressure sensing holes

SPECIFICATIONS

Applications

Liquids and gases

Pipe Sizes

2…24 in . (50…610 mm)

Pressure

400 psi (2760 kPa) maximum

Temperature

250° F (120° C) maximum

Accuracy

±0 .75% of reading

Turndown Ratio

17:1 with no vacuum effect

Standard Components

Y-type head, brass 1/8 in . FNPT connection
Sensor connection:

2…5 in ., Ellipse 1/2 in .; 1/2 in . brass compression fitting with SS ferrule
6…12 in ., Ellipse 7/8 in .; 1 in . CS compression fitting with SS ferrule
14…24 in ., Ellipse 1-1/4 in .; 1-1/4 in . brass compression fitting with SS ferrule

CS 3000 lb thread fitting, ASTM A105
316/316L SS Ellipse sensor
Instrument valves (2 per sensor), 1/4 in . SAE flare brass ball type
Polycarbonate ID tag with wire

Reynolds Number

Greater than 75,000 maintains most accurate flow measurements
Less than 75,000 consult factory for estimated results

Resonance

If greater than 0 .8, use double support

Table 1: Specifications