Installation instructions, double support, Flush with pipe o.d. 2…5 in. models – Badger Meter Model BAR User Manual

Page 6

Advertising
background image

Ellipse® Pitot Tube Meter, BAR Annular Commercial Meter

Page 6

April 2014

INSTALLATION INSTRUCTIONS, DOUBLE SUPPORT

1 . Follow steps 1 through 7 in

“Installation Instructions, Single Support” on page 5

. At 180° from, and on the same plane

as, the previously drilled hole, grind the surface of the pipe to provide a clean area for welding . Drill a hole and de-burr,

especially on the inside of the pipe . The hole used for the double support should be sized according to

Table 3

.

Pipe Size

Model/Sensor

Weld Connector

Drill Bit

2…5 in .

BAR (7/16 in .)

1/2 in .

3/8 in .

6…12 in .

BAR (7/8 in .)

1/2 in .

1/2 in .

14…24 in .

BAR (1-1/4 in .)

1 in .

7/8 in .

Table 3: Double support drill bit size

2 . Weld the double support thread-o-let, making sure that it is centered with the drilled hole (1-1/16 weld

gap recommended) .

3 . Install the BAR Ellipse sensor through the two holes . Make sure that the double support pin passes through the guide ring .

See

Figure 5

.

Flush with

pipe O.D.

2…5 in. Models

Ellipse Sensor

Double Support Pin

Guide Ring

6…24 in. Models

Figure 5: Double support installation

4 . Align the arrow on the sensor head in the direction of flow as in step 9 in

“Installation Instructions, Single Support” on

page 5

.

5 . Make sure the BAR Ellipse is in the correct orientation and spans the inside of the pipe . Manually tighten the compression

nut, then use a wrench to tighten it another 1-1/4 turns .

6 . Install the plug into the end of the double support thread-o-let . Tighten the plug to prevent leakage .

Advertising