3 pin connection option, Figure 12, Figure 13 – Badger Meter Vortex Meters User Manual
Page 14: Meter electronics, Ammeter 8 to 28 vdc power supply, 8 to 28 vdc power supply
Advertising
12
Form No. 09-VRX-UM-00007
3 PIN CONNECTION OPTION
An optional 3 pin connection is available for when the transmitter/meter combination are to be mount-
ed remotely from the power source/receiver. The mating connector is P.N. RF8687000.
+8-28 VDC
Gnd
Output
8 to 28 VDC
Output
White
+4-20 mA Input
Black
-4-20 mA Input
Meter
Electronics
mA
-
+
-
+
Ammeter
8 to 28 VDC
Power Supply
+ 4-20 mA Input
-4-20 mA Input
P.N. RF8687000 Connector
FIGURE 12
+8-28 VDC
Gnd
Output
8 to 28 VDC
Output
Ground
White
Output
Black
- Supply
Green
Ground
Meter
Electronics
-
+
8 to 28 VDC
Power Supply
White
Output
Black
+V
Green
Ground
Counter
P.N. RF8687000 Connector
FIGURE 13