CAUTION ON INSTALLATION LOCATION
(1) A location that provides enough space for periodic inspection and wiring work.
(2) A location not exposed to direct sunlight nor inclement weather.
(3) A location free from excessive vibration, dust, dirt and moisture.
(4) A location not subjected to radiated heat from a heating furnace, etc.
(5) A location not subjected to corrosive atmosphere.
(6) A location not to be submerged.
(7) A location remote from electrical devices (motor, transformer, etc.) which generate
electromagnetic induction noise, electrostatic noise, etc.
(8) A location not subjected to excessive fluid pulsation such as pump discharge side.
(9) A location that provides enough place for the length of the straight pipe.
(10) A location where ambient temperature and humidity are -20 to +50°C and 95% RH or less for
flow transmitter, -20 to +60°C and 100% RH or less for detector.