7.HOLD FUNCTIONS

59

7-5-4. Peak-to-Peak (P-P) Hold

The maximum value of the difference between the peak and valley over the specified

period is held.

The period is specified by the setting of “all period”, “external signal”, “time”, or “time

with trigger”.

(Example) All Period Peak-to-Peak (P-P) Hold

t1 A delay time between the instant when the T/H signal is inputted and the instant

when the indicated value is held
1.0ms (max.)

t2 A delay time between the instant when the T/H signal is released and the instant

when the indicated value returns to tracking
1.0ms (max.)

t3

A minimum reset signal width required for releasing the hold

1.0ms (min.)

Indicated Value

Sensor Input Value

Detection Hold Period

Undetermind

t

T/H

HI-LO Limit
Judging Output

H/E

t2

t1

t3

Standard Line

Hold Section Only

Indicated Value

0

Indicated Value=0

OFF

ON

OFF

ON

OFF

ON

HOLD

OFF

ON

Button

HOLD

Status Display

PEAK

Status Display

ON

Blink

OFF

OFF

OFF

OFF

Period Note

Note: During the undetermined period, the judging output varies with fluctuations in the

input waveform. However, the H/E output remains on during the undetermined

period. Read the judging result when the indicated value becomes stable

(immediately before the T/H signal rises).