Overview – NORD Drivesystems BU0540 User Manual

Page 8

Advertising
background image

SK 500E – Brief instructions for frequency inverters

8

BU 0540 GB-1013

1. Overview

Properties of the basic frequency inverter SK 500E:

• High starting torque and precise motor speed control setting with sensorless current vector

control

• Can be mounted next to each other without additional spacing

• Permissible ambient temperature range 0 to 50°C (please refer to the technical data)

• Integrated EMC mains filter for limit curve A1 (and B1 for size 1 - 4 devices) as per EN55011

(not for 115V devices)

• Automatic measurement of the stator resistance or determination of the precise motor data

• Programmable direct current braking

• Integrated brake chopper for 4 quadrant operation (optional brake resistors)

• Four separate online switchable parameter sets

• RS232/485 interface via RJ12 plug connector

• USS-integrated (see BU 0050)

Feature

SK …

50xE

51xE

511E

520E

53xE

54xE

Additional

options

Operating manual

BU 0500

BU 0505

Safe pulse block (STO / SS1)*

x

x

x

x

BU 0530

2 x CANbus/CANopen interfaces via RJ45
plug

x

x

x

x

BU 0060

RS485 interface additionally via terminals

x

x

x

Speed feedback via incremental encoder
input

x

x

x

Integrated “POSICON” positioning control

x

x

BU 0510

CANopen absolute encoder evaluation

x

x

BU 0510

PLC / SPS – functionality

x

BU 0550

Universal encoder interface
(SSI, BISS, Hiperface, EnDat and
SIN/COS)

x

BU 0510

Operation of PMSM
(Permanent Magnet Synchronous Motors)

x

Modbus RTU

x

BU 0050

Number of digital inputs / outputs**

5 / 0

5 / 0

5 / 0

7 / 2

7 / 2

5 / 3 6 / 2

7 / 1

Additional potential-isolated PTC input***

x

Number of analog inputs / outputs

2 / 1

2 / 1

2 / 1

2 / 1

2 / 1

2 / 1

Number of relay messages

2

2

2

2

2

2

* not with 115 V devices
** SK 54xE: 2 I/Os can be variably parameterised as inputs or outputs
*** alternative "thermistor" function on digital input 5 possible (above size 5 an additional thermistor input is available as
standard)

Table 2: Overview of SK 500E performance grading features

Pos : 21 /Anl eitungen/ Elektroni k/FU und Start er/ 1. Allgemei nes/ 1. 4 Sicherheits- und Inst allati onshi nweis e @ 0\ mod_1325780428207_388. doc x @ 5385 @ 2 @ 1

Advertising