NORD Drivesystems TI 275271019 User Manual

Technical information / datasheet, Sk cu4-eip, Notice

Advertising
background image

Technical Information / Datasheet

EtherNet/IP Bus module

SK CU4-EIP

1.1

LED - Anzeigen / LED displays, Derating

4913

Rck

TI 275900150

GB

version

reason for change(s)

issue

name

document

speech

Pos : 4 /T ec hnis che Inf or mationen/ SK xU x - Bus - Er wei ter ung en/ Et herNet /I P/SK CU 4-EIP / 275271019 / Basisi nf ormati onen [ SK CU4- EI P] @ 4\ mod_1384951329490_388. doc x @ 105631 @ 555 @ 1

SK CU4-EIP

Part number: 275 271 019

EtherNet/IP® - Internal bus – interface

NOTICE

Validity of the documents

This document is only valid in combination with the operating instructions for the relevant frequency inverter. All
of the information that is relevant for a safe start-up of this module and the frequency inverter is only available
under these conditions.

Scope of supply

1 x

Module

SK CU4-EIP

1 x

System bus cable set

grey / black

1 x

24 VDC cable set

brown / blue

2 x

Connecting screws

M4 x 20, cross-head

Field of use

Internal interface for connecting decentralised frequency inverter (SK 180E … SK 2xxE) to a
EtherNet/IP field bus. It is connected to the inverter via the system bus and can respond directly with
up to 4 frequency inverter. 2 digital inputs are available.

Technical data

Module

Temperature range

-25°C … xx °C *

Vibration resistance

3M7

Temperature class

Class 3k3

Firmware version

V1.2 R0

Protection class

IP20

Hardware version

AA

Supply voltage

24 V ± 20

%, ≈ 100 mA

Reverse polarity
protected

* The upper temperature limit depends on the frequency inverter and the operating mode

à see "Derating"

Digital input - working range

Low: 0 V … 5 V, High: 15 V … 30 V

Digital input - specific data

R

i

= 10 kΩ, input capacity: 10nF, reaction time 1 ms, inputs

according to EN 61131-2 type 1

Advertising