Connection examples, Io-extension – sk tu4-ioe-c – NORD Drivesystems TI 275281156 User Manual

Page 5

Advertising
background image

IO-Extension

– SK TU4-IOE-C

TI 275281156 - 4912

5

Potential

Contact

Designation

Description

A

n

a

lo

g

I

O

s

1

VO 10V

10 V 
Reference voltage

2

VO 10V

10 V 
Reference voltage

3

AIN1+

Analog input 1, positive

4

AIN2+

Analog input 2, positive

5

AIN1-

Analog input 1, negative

6

AIN2-

Analog input 2, negative

7

AGND/0V

Analog Ground (internally connected to terminal 40)*

8

AGND/0V

Analog Ground (internally connected to terminal 40)*

9

AOUT

Analog Out

10

PE

PE

S

yste

m

b

u

s le

ve

l

a

n

d

d

ig

ita

l i

n

p

u

ts

11

VI 24V

Supply voltage (+24 V - in)

12

VI 24V

Supply voltage (+24 V - in)

13

VI 24V

Supply voltage (+24 V - in)

14

SYS +

System bus data cable +

15

GND/0V

Reference potential (0 V / GND)

16

SYS -

System bus data cable -

17

GND/0V

Reference potential (0 V / GND)

18

GND/0V

Reference potential (0 V / GND)

19

DIN1

Digital input 1

20

DIN3

Digital input 3

21

GND/0V

Reference potential (0 V / GND)

22

GND/0V

Reference potential (0 V / GND)

23

VI 24V

Supply voltage (+24 V - in)

24

VI 24V

Supply voltage (+24 V - in)

25

DIN2

Digital input 2

26

DIN4

Digital input 4

27

GND/0V

Reference potential (0 V / GND)

28

GND/0V

Reference potential (0 V / GND)

29

VI 24V

Supply voltage (+24 V - in)

30

VI 24V

Supply voltage (+24 V - in)

Di

g

ita

l

o

u

tp

u

ts

31

VI 24V2

Supply voltage (+24 V - in) for digital outputs

32

GND2/0V2

Reference potential (0 V / GND) of digital outputs

33

DOUT1

Digital output 1

34

DOUT2

Digital output 2

35

GND2/0V2

Reference potential (0 V / GND) of digital outputs

36

GND2/0V2

Reference potential (0 V / GND) of digital outputs

Di

a

g

n

o

stic

so

c

ke

t

RJ12 - 1

RS485_A

Data cable RS485

RJ12 - 2

RS485_B

Data cable RS485

RJ12 - 3

GND

Reference potential (GND)

RJ12 - 4

RS232_TxD

Data cable RS232

RJ12 - 5

RS232_RxD

Data cable RS232

RJ12 - 6

24 V

Supply voltage (+24 V)

* AGND/0V is internally connected to the reference voltage of the module GND/0V via a special
component. In order to prevent damage to the module or faults in the analog signals, the two
contacts must not be bridged

Potential level

1 =

2 =

3 =

4 =

Analog IOs

System bus + DIN

DOUT

Diagnosis

Pos : 12 /T echnisc he I nf ormati onen/I O - Er weit er ung/ Ans chl uss beis piel e [IO E Allgemei n] @ 2\ mod_1352736753713_388. doc x @ 51105 @ 6 @ 1

Connection examples

The following connection examples are generally applicable for NORD IO modules. The number or
type of the available IOs and their configuration on the terminal rail varies according to the module.
The actual availability or the designation of the individual contacts should be obtained by reference to
the description of the connections. The technical data (e.g. load capacity) must be taken into account.

Advertising