background image

POWERLINK Bus module – SK TU3-POL

2

TI 2752900140 - 4913

Bus specification

POWERLINK

Max. 100 MBaud

Cable

Min. Ethernet CAT-5

Electrical isolation 500 V

eff

Max. cable length

100 m between two
modules

Bus connection

2 x RJ45

Shield

via RJ sockets high-

bus termination

Takes place automatically

Ohmic & capacitive to PE

Status display

6 LEDs

PE connection

via PE post-type connector

Topology*

Star, tree, linear bus

(rating less than 24 V)

Performance

Update interval for process data between module and frequency inverter

≈ 1.5 ms

Parameter read access on the frequency inverter

≈ 25 ms

Parameter write access with storage in EEPROM

≈ 70 ms

Cycle times

400 µs … 60 ms

Pos : 6 /T ec hnis che Inf or mationen/ SK xU x - Bus - Er wei ter ung en/ Powerlink/M erkmal e [ PO L Allgemei n] @ 3\ mod_1377869060850_388. doc x @ 92057 @ 5 @ 1

Module features

Hot Plugging (CN connection during operation)

Yes

Isochronous (PDO)

Yes, Statistical Mapping

Number of process data

12 Byte (SK TU3-…),
50 Byte (SK xU4-…)

Asynchronous Data (SDO over ASND or UDP/IP)

Yes

Cross Traffic

No, no direct communication between CN

Addressing via

DIP switch, module parameters possible

Access for NORD diagnosis tool via

Diagnostic socket on the device (if available) or possibly
via frequency inverter and UDP Ethernet protocol

Pos : 9 / Anl eit ung en/El ektr oni k/FU und St arter/ 3. / 4. Anzeige und Bedienung [ BU 0500 / BU 0200]/SK 5xxE/ 3. 2 Ü bersic ht der T echnologieboxen - 2- Mont age @ 1\ mod_1340712929975_388. doc x @ 28340 @ 5 @ 1