Installation data, Commissioning and operating information, Scope of delivery – NORD Drivesystems TI059_19140990 User Manual

Page 2: Connections, Getriebebau nord gmbh & co. kg

Advertising
background image

 

Getriebebau NORD GmbH & Co. KG

 

Rudolf-Diesel-Straße 1 · D-22941 Bargteheide

Tel.: +49 45 32 - 40 10 · Fax: +49 45 32 - 40 12 53 · www.nord.com

SK EBGR-1

1.8

Supplement to series ID

28.02.11

Rck

TI 059 19140990

2/2

1.7

Radio interference suppression C2, Supplement of brake release/application times

21.02.11

Rck

Version Amendment

Date

Name Document

Page

 

Signal request from
FI: ON = "Release
brake"

Brake switching
state: ON= "Brake
released"

 

(Brake is supplied
with current)

Connections

Terminals

Screw terminals

4 terminal blocks, each with 3 connections, (7.5mm spacing)

Cable cross section

0.2…2.5 mm

AWG 12-30

PE connection

via snap-on DIN rail

The snap-on rail must be grounded

Terminal

PIN

Description

Contact
No.

1

 

Top layer

PIN 1

Supply voltage (+24V)

44

PIN 2

Digital input for DC brake switching

C5

PIN 3

Reference potential (0V/GND)

40

2
Top layer

PIN 1

Supply voltage 380V … 500V ±10% AC (L1)

L1

E

PIN 2

Supply voltage 100V … 275V ±10% AC (L1)

L1

B

PIN 3

Reference potential (N/L2)

N/L2

3
Bottom layer

PIN 1

Supply voltage (+24V) - as for terminal 1 PIN 1 (internally bridged)

44

PIN 2

Digital output (output to SPS)

B5

PIN 3

Reference potential (0V/GND) - as for terminal 1 PIN 3 (internally bridged)

40

4
Bottom layer

PIN 1

Brake connection +

79

PIN 2

-

-

PIN 3

Brake connection -

80

Installation data:

 

Dimensions: [mm]

H85xW22.5xD70.4

Mounting:

Snap-on rail mounting (35mm snap-on DIN rail)

Commissioning and operating information:

 

Observe the brake coil voltage! Select the correct mains voltage and connect the appropriate contact.
NOTE:

Incorrect voltage or incorrect connection of the supply voltage (L1

E

or L1

B

) may cause

destruction of the SK EBGR 1 and the brake coil!

 

Brake coil voltage

Mains voltage

Terminal PIN

Contact No.

205V DC

230V AC

2

2 + 3

L1

B

+ N/L2

180V DC

400V AC

2

1 + 3

L1

E

+ N/L2

205V DC

460V AC or 480V AC

2

1 + 3

L1

E

+ N/L2

Brake control: Set digital input = Brake released.
The device must be provided with a 24V control voltage.
NOTE: Make a GND connection between the frequency inverter and the SK EBGR-1.


Scope of delivery:

 

Electronic brake rectifier SK EBGR-1 without other accessories

Terminal 1

Terminal 3

Terminal 2

Terminal 4

Advertising