8

http://muting.reer.it

JANUS MI TRX, MI TRXL

Janus MI TRX and MI TRXL consist of one active emitter/receiver element and one retro-reflecting
passive element which does not need electrical connections.

▪Models MI TRX with M12 front connectors for external Muting sensors with 2 or 4-sensor

logics for both two-way entry/exit (2 – 4 sensors) and one-way (2 sensors) exit only.

▪Models MI TRXL with single connector M23 with 2-sensor logics for two-way entry/exit (2

sensors)

▪2 - 3 - 4 beams for detection of the body in access monitoring

▪Max range 6 m.

JANUS ML TRX, ML TRX G

Janus ML TRX and ML TRX G, 2 or 3 beams for access monitoring have an original 2-horizontal
arms system – one for active side and one for passive side – with built-in Muting photoelectric
sensors, prewired and prealigned.

Models ML TRX G are designed to ensure reliable detection of glass and other transparent
materials.

Both light grid and Muting sensors consist of one active emitter/receiver element and one
retro-reflecting passive element which does not need electrical connections.

▪One-way Muting logics, exit only

▪2 and 3 beams for detection of the body in access monitoring

▪Max range 3,5 m models TRX (2 m TRX G)

▪Optoelectronic Muting sensors with 2 parallel beams.

JANUS MT TRX, MT TRX G

Janus MT TRX and MT TRX G, 2 or 3 beams for access monitoring have an original 4-horizontal
arms device (2 for active side and 2 for passive side) with built-in Muting photoelectric sen-
sors, prewired and prealigned.

Models MT TRX G are designed to ensure reliable detection of glass and other transparent
materials.

Both light grid and Muting sensors consist of one active sensor emitter/receiver and one retro-
reflecting passive sensor which does not need electrical connections.

▪Two-way Muting logics, entry/exit

▪2 and 3 beams for detection of the body in access monitoring

▪Max range 3,5 m models TRX (2 m TRX G)

▪Optoelectronic Muting sensors with 4 parallel beams.

Models ML, ML TRX and ML TRX G and MT, MT TRX and MT TRX G are quick and easy to install. Also, they are complying with
regulatory requirements on Muting sensor geometry and all other safety-related parameters, as per IEC TS 62046 and other
current standards.

Active

Passive

Active

Passive

Active

Passive