Technical specifications – Ouellet TH115 User Manual

Page 23

Advertising
background image

TH115-AF-GA / TH115-AF-GB

21

ENG

LISH

Display range

: 0°C to 70.0°C (32°F to 158°F)

Ambient setpoint range (A/AF modes)

: 5.0°C to 30.0°C (40°F - 86°F)

Floor setpoint range (F mode)

: 5.0°C to 40.0°C (40°F - 104°F)

Floor limit range (AF mode)

: 5.0°C to 40.0°C (40°F - 104°F)

Resolution

: 0.5°C (1°F)

Heating cycle length

: 15 minutes

Data protection

: In the event of a power failure, most settings are saved. However the time and Daylight

Saving Time must be set if the power failure lasts more than 6 hours. The thermostat will return to the
mode that was active prior to the power failure.

Technical Specifications

Model

Supply

Max. load (resistive only)

Ground Fault

Protection

(GFCI)

Wiring

Current

Power

TH115-AF-GA

120 VAC, 60 Hz

15 A

1800 W

5 mA

4 wires,

double pole

240 VAC, 60 Hz

3600 W

TH115-AF-GB

120 VAC, 60 Hz

1800 W

15 mA

240 VAC, 60 Hz

3600 W

400-115-051-B (Honeywell TH115-AF-GA_GB) 5 x 3.125 EFS.book Page 21 Monday, April 12, 2010 3:10 PM