Important!

Setting either the CNV>BB or BB CYC parameters to “0” will disable
the blowback feature. DO NOT set other blowback parameters to “0.”

5-2-1-1-3 Input and Output Screen Features

To access the I/O screen, press the right arrow
key (►) when the Blowback Parameter screen
is displayed or the left arrow key (◄) when the
Convey/Dump/No Convey screen is displayed.

The I/O screen allows a service technician to
view the status of the controller’s inputs and
outputs during operation.

5-2-1-1-4 Changing Parameters

To change the settings in the Conveying, Pump
Parameters, or Blowback screens {To access
the required screen, press the right (►) or the
left arrow key (◄)}, the following operations will
need to be performed:

1. When the controller is in the menu screen

of the feature you wish to configure, press
the up (▲) and down (▼) arrow keys to
select the value you wish to change. (The
parameter value will flash when selected.)

2. Use the Plus (+) key to increase the value

or the Minus (-) key to decrease the value.

3. Press the OK key to update and accept the

new value entered.

4. Press the ESC key to cancel the

parameters you entered and return the
values to the previous settings.

5-2-2 Starting

the

System

Once you have finished the setup procedues described on
the previous pages, you are now ready to start the system.
To start your system, complete the following steps.