Upright Portable Hot Oil TCUs Chapter 2: Functional Description

16

Fail Safe Operation

If a safety device or circuit should fail, the design must be such that the failure causes a
“Safe” condition. As an example, a safety switch must be a normally open switch. The switch
must be held closed with the device it is to protect. If the switch fails, it will go to the open
condition, tripping out the safety circuit.

At no time should the safety device fail and allow the operation to continue. For example, if
a safety switch is guarding a motor, and the safety switch fails, the motor should not be able
to run.

Safety Device Lock-Outs

Some safety devices disconnect electrical energy from a circuit. The safety devices that are
used on these temperature control units are primarily concerned with electrical power
disconnection and the disabling of moving parts that may need to be accessed during the
normal operation of the machine.

Some of the safety devices utilize a manual activator. This is the method of initiating the
safety lock out. This may be in the form of a plug, lever or a handle. Within this lockable
handle, there may be a location for a padlock. Personnel servicing the equipment should
place a padlock in the lockout handle.

In addition to the safety devices listed above, these temperature control units are equipped
with a line cord plug. This allows the operator or maintenance personnel to unplug the tcu
from its power source and tag it out. The plug can then be tagged with any number of
approved electrical lockout tags available at most electrical supply stores.

WARNING!

Always disconnect and lockout all electrical power and pneumatic (i.e. compressed air)
sources prior to servicing or cleaning the temperature control unit. Failure to do so
may result in serious injury. No one but the person who installed the lockout may
remove it.