CONTROL PANEL 3 - 32

HL7050_US_UG_FM5.5

INTERFACE

Display Shows

Description

SELECT

=AUTO/PARALLEL/RS-232C/USB/NETWORK

AUTO IF TIME

= 1:99 (sec)

You need to set the time-out period for the auto interface
selection.

INPUT BUFFER

= Level1:15

Increase or
decrease the input
buffer capacity.

RESTART PRINTER?

PARALLEL

When using the parallel interface

Sub-setting Menu

Description

HIGH SPEED

=ON/OFF

Turns high-speed parallel
communications on or off.

BI-DIR

=ON/OFF

Turns bi-directional parallel
communications on or off.

RS-232C

When using the serial interface

Sub-setting Menu

Description

FAX MODE

=OFF/ON RESTART

PRINTER?

BAUDRATE

*1

Data transfer speed can be set to
150/300/600/1200/2400/4800/9600/
19200/38400/57600/115200 baud.

CODETYPE

*1

=8 BITS/7 BITS

The data length can be set to 7 or 8
bits.

PARITY

*1

=NONE/ODD/EVEN

The data error check can be set to
NONE, ODD or EVEN.

STOP BIT

*1

=1 BITS/2 BITS

The data separator can be set to 1 or
2 stop bits.

XON/XOFF

*1

=ON/OFF

Handshake protocol can be set to on
or off.