System messages – Canon VB-M40 User Manual

Page 130

Advertising
background image

7

-16

„ HTTP Server Messages

H143 User name specification error [notice]

H144 Password specification error [notice]

H145 Connection denied due to host access limitation [notice]

H201 Timeout disconnect [warning]

„ System messages

S001 System started [info]

S002 System settings changed [info]

S010 Event service started [info]

S011 Event service shut down [info]

Description

(http_auth.c.XXX) get_password failed (H143)

Meaning

An unknown user was specified in user authentication.

Description

(http_auth.c.XXX) password doesn't match for %1 %2, IP:%3 (H144)

%1

URL XSS vulnerability countermeasure implementation (process equivalent to ftpd)

%2

User Name

%3

IP address

Meaning

A wrong password was specified in user authentication.

Description

(mod_haccess.c.XXX) host %1 access denied (H145)

%1

IP address

Meaning

Connection was denied due to access limitation imposed on the host.

Description

a request for %1 timed out after writing %d seconds (H201)

%1

Request URI

%d

360 (Timeout time)

Meaning

Disconnected due to HTTP server timeout (360 sec.).

Description

starting paramd (S001)

Meaning

Parameter management module started.

Description

Updated system settings. (S002)

Meaning

Settings not requiring rebooting were changed.

Description

starting event (S010)

Meaning

The event service was started.

Description

shutdown event (S011)

Meaning

The event service was shut down.

Advertising