Canon imagePROGRAF iPF6450 User Manual

Page 48

Advertising
background image

Note

If the Spectrophotometer Unit is mounted, grasp the blue
handles on the left and right sides of the Spectrophotom-
eter Eject Guide and remove the Spectrophotometer
Eject Guide from the Spectrophotometer Unit.

3

Pull out the used Maintenance Cartridge by the grip
(a). Holding the cartridge by the handles (b) on
both sides, keep the cartridge level as you remove
it.

Important

Used Maintenance Cartridges are heavy. Remove and store the used Maintenance Cartridge, making sure to
keep it secure and level. If you drop a used Maintenance Cartridge or store it an angle, ink may leak and
cause stains.

The remaining Maintenance Cartridge capacity is stored on each printer. Do not install a used Maintenance
Cartridge in another printer.

Note

If the printer has a Spectrophotometer Unit, look
under the Spectrophotometer Unit to check the
position of the Maintenance Cartridge before re-
moving it.

4

Keep the used Maintenance Cartridge level as you
put it in the plastic bag that was in the box, as
shown.

Replacing the Maintenance Cartridge

iPF6450

Basic Guide

Consumables and Maintenance

Maintenance Cartridge

48