Note

•

If printing does not improve after Head Cleaning B, try repeating Head Cleaning B once or twice. If this still does not
improve printing, the Printhead may have reached the end of its useful life. Contact your Canon dealer for assistance.

•

Nozzles are periodically checked to ensure they are clear. Configure the settings on the Control Panel menu in Nozzle
Check
. (See "Menu Settings.")

→User's Guide

Perform cleaning as follows.

1

On the Tab Selection screen of the Control Panel, press

◀ or

▶ to select the Settings/Adj. tab (

).

Note

•

If the Tab Selection screen is not displayed, press the Menu button.

2

Press the OK button.
The Set./Adj. Menu is displayed.

3

Press ▲ or ▼ to select Maintenance, and then press the OK button.

4

Press ▲ or ▼ to select Head Cleaning, and then press the OK button.

5

Press ▲ or ▼ to select Head Cleaning A or Head Cleaning B, and then press the OK button.
Head cleaning is now executed.

6

Print a test pattern to check the nozzles, and determine whether cleaning has cleared the nozzles. (See
"Checking for Nozzle Clogging.")

→User's Guide

Cleaning the Spectrophotometer Unit (option) Parts

Cleaning the Spectrophotometer Unit (option) Parts

Clean the Spectrophotometer Unit parts as follows.

Cleaning the White Calibration Tile

1

Turn the printer off.
(See "Turning the Printer On and Off.")

→User's Guide

2

Unplug the power cord from the outlet.

Caution

•

Always turn off the printer and unplug the power cord before cleaning or maintenance. Accidentally leaving the
printer on poses a risk of injury if you touch moving parts inside the printer.

Cleaning the Spectrophotometer Unit (option) Parts

iPF6450

Basic Guide

Consumables and Maintenance

Cleaning the Printer

54