VOLTAGE CHECKING TYPE:

Enter Start Feature ‘D’ Programming Mode:
1. Turn the Ignition ‘switch ‘ON/OFF’ 3 TIMES and stay in OFF
position.
2. Push the Valet switch 9 times (holding in on the 9th push) until four

chirps with a long chirp is heard then release the valet switch. You are
now in the Start feature ‘D’ programming mode.

Select “Checking Type”:
3. Press the transmitter

+

button to set the “Voltage Checking

Type”. [2] LED flash, [2] horn chirp to confirm this setting

Once you complete step 3, you can adjust and test “Start Timer” as below:

VOLTAGE START PROGRAMMING: (TEST & ADJUST)

While the system is in Start Feature “D” programming mode,
1. Press the

button on the transmitter to start the vehicle.

2. If everything goes well: Wait 10 seconds:

a. If the engine is still running.

I. Press the

button on the transmitter to stop engine.

You have completed this programming successfully.
II. Press

button on the transmitter to exit the program mode.

There will be 3 long chirps & 3 parking light flashes for confirmation.
b. If the engine shuts down after the vehicle has started:

I. Press the ‘

button on the transmitter to stop the engine.

II. Press

button on the transmitter to set “Check Level” to LOW

position. [1] LED flash, [1] Siren chirp to confirm this setting
III. Repeat the steps 1 – 2 if necessary.

3. If the crank time is too long, (Engine running but starter still cranks):

a. Press the

button on the transmitter to stop the engine.

b. Press

button on the transmitter to set proper “Start Timer”. The

chirp & LED pause will confirm this entry. (Decrease “Start Timer” is
necessary.)

4. If the crank time is too short,(The engine is not running and the starter

has stopped cranking):

a. Press

button on the transmitter to set proper “Start Timer

”.

The

chirp & LED pause will confirm this entry. (Increase “Start Timer” is
necessary.)