Operation test, Check after installation – Electrolux EXH09HL1WI User Manual

Page 22

Advertising
background image

22

www.electrolux.com

16. Securely tighten the cap of the

packed valves.

Outdoor condensate drainage (heat-
pump unit only)
During heating operation, condensate
water and defrosting water must be
drained through the drain hose.

1. Install the outdoor drain connector in

a Ø 25 mm hole on the base plate.

2. Attach the drain hose to the

connector so that water in the
outdoor unit can be drained. The
hole diameter 25 must be plugged.

Operation test

Before operation test
r© $O©NOT©CONNECT©THE©UNIT©TO©THE©POWER©

supply before the installation is
completed.

r© 4HE©ELECTRICAL©WIRING©MUST©BE©

connected correctly and securely.

r© 4HE©CUT OFF©VALVES©OF©THE©CONNECTION©

pipes must be opened. Refer to the
section “Vacuuming and leakage
test”.

r© 4HE©UNIT©MUST©BE©CLEANED©THOROUGHLY

Operation test method
1. Connect the unit to the power

supply.

2. Press the ON/OFF button to switch

on the unit.

3. Press the MODE button to set the

operation mode and check whether
the operation is as expected.

Check after installation

Items to be checked

Possible malfunction

Has the unit been jxed jrmly?

The unit may drop, shake or emit noise.

Have you done the refrigerant leakage
test?

Insufjcient cooling or heating.

Is the thermal insulation sufjcient?

Condensation.

Is the water drainage satisfactory?

Water leakage.

Is the voltage in accordance with the
rated voltage on the nameplate?

Electrical malfunction or damage to the
unit.

Is the electrical wiring or piping
connection installed correctly and
securely?

Electrical malfunction or damage to the
parts.

Has the unit been securely grounded?

Electrical leakage.

Is the mains cable as specijed?

Electrical malfunction or damage to
parts.

Is the air inlet or the air outlet blocked?

Insufjcient cooling or heating.

Is the length of the connection pipes
and the refrigerant capacity as specijed

Inaccurate refrigerant capacity.

Is the length of the connection pipes
and the refrigerant capacity as specijed

Inaccurate refrigerant capacity.