Anti-cold air function

In HEAT mode, the indoor fan will not
operate in order to prevent cold air from
blowing out if the indoor heat exchanger
does not reach a certain temperature in
one of the following situations:
r© WHEN©THE©HEATING©OPERATION©STARTS
r© WHEN©THE©DEFROSTING©OPERATION©IS©

kNISHED

r© WHEN©HEATING©AT©LOW©TEMPERATURE

Gentle breeze

The indoor unit may blow gentle breeze
and the horizontal louvre rotates to a

certain position in one of the following
situations:
r© )N©(%!4©MODE ©THE©COMPRESSOR©DOES©

not start operation after switching on
the unit.

r© )N©(%!4©MODE ©THE©TEMPERATURE©

reaches the set value and the
compressor has stopped operation
for 1 minute.

Opetaring temperature range

The operating temperature range for
cooling-only units is -15-(+48)˚C. The
operating temperature range for heat-
pump units is -20-(+24)˚C.

Tip for energy saving

r© $O©NOT©OVERCOOL©OR©OVERHEAT©3ETTING©

the temperature at a moderate level
helps energy saving.

r© #OVER©WINDOWS©WITH©A©BLIND©OR©A©

curtain. Blocking sunlight and air from
outdoor is favorable for cooling.

r© #LEAN©AIR©kLTERS©EVERY©TWO©WEEKS©

Clogged air filters lead to inefficient
operation and energy waste.

Tip for relative humidity

r© )F©THE©UNIT©IS©OPERATED©IN©AN©AREA©WITH©

a relative humidity of more than 80%
for a long time, condensate may drip
from the indoor unit.

Installation notes

r© .OT©FOLLOWING©THE©INSTRUCTIONS©CAN©

cause personal injury and/or property
damage.

r© .OT©FOLLOWING©THE©INSTRUCTIONS©CAN©

cause the unit to fail.

r© ,ET©THE©UNIT©BE©INSTALLED©BY©AN©

authorised service centre.

r© ,ET©THE©UNIT©BE©INSTALLED©IN©COMPLIANCE©

with local and governmental
regulations.

r© ,ET©THE©UNIT©BE©INSTALLED©ACCORDING©TO©

the instructions from this manual.

r© &IRST©CONTACT©AN©AUTHORISED©SERVICE©

centre before relocating an already
installed unit

r© $ISCONNECT©POWER©BEFORE©WORKING©ON©

the unit.

r© ,ET©THE©MAINS©CABLE©BE©REPAIRED©BY©AN©

authorised service centre or qualified
technician for units with Y-attachment.

r© 4HE©MAINS©PLUG©MUST©REMAIN©

accessible after installation.

r© +EEP©SUFkCIENT©DISTANCE©BETWEEN©

the interconnection cable and the

Indoor side (°C)

Outdoor side (°C)

Max. cooling

32

48

Min. cooling

21

-15

Max. heating

27

24

Min. heating

20

-20

INSTALLATION