Installation test (duct) – LG DLEX3570W User Manual

Page 29

Advertising
background image

29

ENGLISH

Installation test (Duct)

Once you have completed the installation of the dryer,
use this test to make sure the condition of the exhaust
system is adequate for proper operation of the dryer.
This test should be performed to alert you to any serious
problems in the exhaust system of your home.

t:PVSESZFSGFBUVSFTFLOW SENSE

TM

, an innovative

sensing system that automatically detects blockages
BOESFTUSJDUJPOTJOESZFSEVDUXPSL,FFQJOHEVDUXPSL
clean of lint buildup and free of restrictions allows
clothes to dry faster and reduces energy use.


5PBDUJWBUFUIF*OTUBMMBUJPOUFTU

3FNPWFUIFESZJOHSBDLBOEMJUFSBUVSF BOEUIFO

DMPTFUIFEPPS
Do not load anything in the drum for this test, as in
may affect the accuracy of the results.

1SFTTBOEIPMEUIF4*(/"-0/0''BOE5&.1

$0/530-CVUUPOTBOEUIFOQSFTTUIF108&3
CVUUPO
This button sequence activates the
installation test. The code

will display if the

activation is successful.

3.

1SFTT45"351"64&CVUUPO
The dryer will start the test, which will last about
two minutes. The heat will be turned on and the
temperatures in the drum will be measured.

4.

$IFDLUIFEJTQMBZGPSSFTVMUT
During the two minute test cycle, monitor the FLOW
SENSE

TM

display on the control panel. If no bars

are displayed, when the cycle ends, the exhaust
system is adequate. If the exhaust system is severely
restricted, the display will show four bars.
Other problems may also be shown with error codes.
Refer to the next page for error code details and
solutions.

Four bars indicates that the exhaust system is severely
restricted. Have the system checked immediately, as
performance will be poor.

&OEPGDZDMF

At the end of the test cycle,

will display.

The test cycle will end and the dryer will shut off
automatically after a short delay.

NOTE

The dryer should be cool before starting this test. If
the dryer was warmed up during installation, run the
AIR DRY cycle for a few minutes to reduce the interior
temperature.

/0#"34

0,

'063#"34
RESTRICTED

INSTALLATION INSTRUCTIONS

Advertising
This manual is related to the following products: