Control Locations

Owner’s Manual 15

ENGLISH

Self-Diagnosis

FUNCTION:

If the unit has a malfunction, a green OPERATIONLED located on the Display PCB used by the unit to
indicate the errors.

USE:

If the customer has to register a complaint to the service center, he can be very clear about registering
the complaint that what is happening & by referring the user's manual the customer can clearly define
the problem.
So that the engineer should go fully prepared with the prescribed tools to be used regarding that
problem. It also keeps the customer aware about the unit.
Here are some of the problems defined below for which the LED indicates by flashing number of times
the error has been reconrded against it.
The errors are the mentioned in the (Table 13) which is as follows:

ON

Normal

OFF

No power / failed board

Fault Codes

CH 01

Indoor Air Thermistor Error

CH 02

Indoor Coil Thermistor Error

CH 03

Outdoor Air Thermistor Error (PTHP Only)

CH 04

Outdoor Coil Thermistor Error (PTHP Only)

CH 05

Mode Error

CH 06

Setpoint Error

CH 07

Bad Thermistor Wiring