4 alarm in / out – Approach Tech DVR-3024M User Manual

Page 10

Advertising
background image

8

ALARM1 IN

ALARM4 IN

ALARM2 IN

ALARM3 IN

ALARM OUT

RECORD IN

GROUND

DISK FULL

ALARM RESET

1

2

3

4

5

6

7

8

9

5V

0V(Active)

5V

0V(Active)

1.4 ALARM In / Out








The above figure is the rear view.

1. GND:

Ground Contact.

2. ALARM

OUT

(OUTPUT):

This is an

alarm output trigger. Connect this to

external devices such as buzzers or

lights.

5V

0V(Active)

3. DISK FULL (OUTPUT): This is a disk full

output trigger. Connect this to external

devices such as buzzers or lights.

5V

0V(Active)

4. ALARM RESET (INPUT): This pin

connects to an alarm-clear device for

clearing an alarm.

5V

0V(Active)

5.

RECORD IN (INPUT): This pin connects

to a record trigger device for starting a

record.

6. ALARM4 IN (INPUT): This is an alarm

input (for CH 4), which can be

programmed in the menu system to

Normally Open or Normally Closed.

7.

ALARM3 IN (INPUT): same as the above,

for CH 3

8.

ALARM2 IN (INPUT): same as the above,

for CH 2

9.

ALARM1 IN (INPUT): same as the above,

for CH 1


Advertising