2 alarm / motion setting – Approach Tech DVR-3024M User Manual

Page 31

Advertising
background image

29

RECORD

ALARM / MOTION

CLOCK/ TIMER
COMMUNICATION
DISK
SYSTEM

MAIN MENU

GOTO ALARM/ MOTION PAGE

RECORD

ALARM / MOTION

CLOCK/ TIMER
COMMUNICATION
DISK
SYSTEM

MAIN MENU

GOTO ALARM/ MOTION PAGE

NOTE: The 30 F/S (25 F/S for a PAL unit)

recording rate can only function in a

352x240 (352x288 for a PAL unit) resolution.

REC QUALITY:

This option determines the image quality to

be recorded. The DVR stores images in the

compressed format and allows the image

quality to be altered by the image size.

There are 4 levels of image quality you can

select from: BEST, HIGH, STANDARD, and

BASIC. Selecting the BEST image for use

provides higher-resolution recorded images,

and normally takes up more storage space

than a HIGH, STANDARD or BASIC image

does.

DISK FULL:

This option determines the way to utilize

storage media in case of a full disk.

REWRITE: When the hard-disk is full, the

device continues recording by displacing the

old data.

STOP: When the hard-disk is full, the device

will stop recording.

AUDIO: This option determines the way to

record sound if necessary.

ON: Enables AUDIO recording.
OFF: Disables AUDIO recording.

4.2 ALARM / MOTION Setting








This menu allows users to program the

configuration of alarm recording only when an

alarm input is activated. The device will

record as long as the alarm input is activated.


ALM OPERATION:

This option determines whether to

activate/deactivate the alarm recording when

it detects an alarm input.

ON: The device activates the alarm recording

when it detects an alarm input.

OFF: The device ignores the alarm signal

when it detects an alarm input.

AUDIO:

This option determines the way to record

sound if necessary.

OFF: Disables AUDIO recording.

ON: Enables AUDIO recording.

ALM TYPE:

This option allows users to set a type of alarm

input corresponding to the sensor signal in

use.

NO: Normally Open. This is to be used with

the type of alarm sensor whose contact

remains open in normal conditions and

ALARM/MOTION


ALM OPERATION : OFF
AUDIO

:

OFF

ALM TYPE

: NO

ALM DURATION

: 30 SEC

PRE-ALARM

:

OFF

MOTION SETTING

MAIN PAGE


ALARM RECORD ENABLE

Advertising