Installation instructions, Electrical connections, Warning – LG LCE30845 User Manual

Page 23

Advertising
background image

23

IMPORTANT SAFETY INSTRUCTIONS

Be sure your cooktop is installed and grounded
properly by a qualified installer or service
technician.

This cooktop must be electrically grounded in
accordance with local codes or, in their
absence, with the National Electrical Code
ANSI/NFPA No. 70, latest edition in the
United States.

ELECTRICAL CONNECTIONS

INSTALLATION INSTRUCTIONS

The electrical power to the cooktop must be
shut off while line connections are being
made. Failure to do so could result in
serious injury or death.

PROVIDING THE
ELECTRICAL CONNECTION

Install the junction box under the cabinet and run
120/240 or 120/208 volt, AC wire from the main
circuit panel.

NOTE: DO NOT connect the wire to the circuit
panel at this time.

ELECTRICAL REQUIREMENTS

Observe all governing codes and local
ordinances.

A 3-wire or 4-wire single-phase 120/240 or
120/208 volt, 60 Hz AC-only electrical supply
is required on a separate circuit fused on
both sides of the line (time-delay fuse or
circuit breaker is recommended). DO NOT
fuse neutral. The fuse size must not exceed
the circuit rating of the appliance specified on
the nameplate.

This unit can consume up to 7,400W at
240 VAC. A 40 Amp circuit breaker with wire
gauge #8 AWG must be used.

NOTE: Wire sizes and connections must
conform with the fuse size and rating of the
appliance in accordance with the National
Electrical Code ANSI/NFPA No. 70, latest
edition, and local codes and ordinances.

The appliance should be connected to the
fused disconnect (or circuit breaker) box
through flexible armored or nonmetallic
sheathed cable. The flexible armored cable
extending from this appliance should be
connected directly to the grounded junction
box. The junction box should be located as
shown on page 22 with as much slack as
possible remaining in the cable between the
box and the appliance, so it can be moved if
servicing is ever necessary.

A suitable strain relief must be provided to
attach the flexible armored cable to the
junction box.

1

2

3

4

An extension cord must not be used with
this appliance. Such use may result in a fire,
electrical shock, or other personal injury.

WARNING

WARNING

ENGLISH

Advertising
This manual is related to the following products: